XEAST is a Leading Supplier & Manufacturer of Professional Testing and Measuring Instruments in China.
Product Introduction
Hantek2000 Series An all-new handheld oscilloscope-Hantek2000 series, it continues the compact and lightweight concept but with a new generation of 3 in 1 multifunction tester: oscilloscope, signal source and multimeter; A small volume of the non-profit grip by a single hand; The suspendingstand was designed to support multi-angle adjustment; Ultra-low-power, Type C charging interface, each 2 hours battery charge allow working one full day or standbytwo months; High-definition color LCD screen display clear and delicate; Minimalist keyboard design simplifyoperation, easy to use.
Product Features
Product Display
Key Specifications
Model |
Hantek2D72 |
Hantek2D42 |
Hantek2C72 |
Hantek2C42 |
Oscilloscope Mode |
||||
Bandwidth |
70MHz |
40MHz |
70MHz |
40MHz |
Channel |
2CH+DMM+AWG |
2CH+DMM+AWG |
2CH+DMM |
2CH+DMM |
Horizontal |
||||
Sample Rate Range |
250MSa/s(Single-channel), 125MSa/s(Dual-channel) |
|||
Waveform Interpolation |
(sin x)/x |
|||
Record Length |
Max. 6K for single-channel; 3K samples per dual-channel |
|||
SEC/DIV Range |
5ns/div~500s/div 1, 2, 5 sequence |
|||
Vertical |
||||
A/D Converter |
8-bit resolution,each channel sampled simultaneously |
|||
VOLTS/DIV Range |
10mV/div~10V/divat input BNC |
|||
Bandwidth Limit, typical |
20MHz |
|||
Low Frequency Response (-3db) |
≤10Hz at BNC |
|||
Rise Time at BNC, typical |
≤5ns |
|||
DC Gain Accuracy |
±3% for Normal or Average acquisition mode, 10V/div to 10mV/div |
|||
Note: Bandwidth reduced to 6MHz when using a 1X probe. |
||||
Acquisition |
||||
Acquisition Modes |
Normal |
|||
Trigger |
||||
Type |
Edge |
|||
Mode |
Auto, Normal, single |
|||
Level |
±4 divisions from center of screen |
|||
Trigger Level Accuracy |
0.2div × volts/div within ±4 divisions from center of screen |
|||
Slope |
Rising, Falling, Rising & Falling |
|||
Source |
CH1/CH2 |
|||
Input |
||||
Coupling |
DC, AC or GND |
|||
Input Impedance, |
25pF±3 pF, 1MΩ±2% |
|||
DC coupled |
||||
Probe Attenuation |
1X, 10X |
|||
Supported Probe Attenuation Factors |
1X, 10X, 100X, 1000X |
|||
Maximum Input Voltage |
150VRMS |
|||
Measurement |
||||
Cursor
|
Voltage difference between cursors: △V |
|||
Time difference between cursors: △T |
||||
Automatic Measurements |
Frequency, Amplitude |
|||
Arbitrary Waveform Generator Mode |
||||
Waveform Frequency
|
Sine: 1Hz~25MHz |
- |
- |
|
Square: 1Hz~10MHz |
- |
- |
||
Ramp: 1Hz~1MHz |
- |
- |
||
EXP: 1Hz~5MHz |
- |
- |
||
Sampling |
250MSa/s |
- |
- |
|
Amplitude
|
2.5Vpp(50Ω) |
- |
- |
|
5Vpp(High impedance) |
- |
- |
||
Frequency Resolution |
0.10% |
- |
- |
|
Channel |
1CH waveform output |
- |
- |
|
Waveform Depth |
512Sa |
- |
- |
|
Vertical Resolution |
12 bit |
- |
- |
|
Output Impedance |
50 Ω |
- |
- |
|
DMM |
||||
Maximum Resolution |
4000 Counts |
|||
DMM Testing Modes |
Voltage,Current,Resistance,Capacitance,Diode &On-Off |
|||
Maximum Input Voltage |
AC:600V, DC: 600V |
|||
Maximum Input Current |
AC: 10A, DC:10A |
|||
Input Impedance |
10MΩ |
|||
Measurement Term |
Range |
Accuracy |
Resolution |
|
DC Voltage
|
400.00mV |
± (0.8% + 5) |
100uV |
|
4.000V |
|
1mV |
||
40.00V |
|
10mV |
||
400.0V |
|
100mV |
||
600.0V |
± (1% + 2) |
1V |
||
Overload protection: 400mV: 250V, other: 600Vrms. |
||||
AC Voltage
|
4.000V |
± (1.2% + 5) |
1mV |
|
40.00V |
|
10mV |
||
400.0V |
|
100mV |
||
600.0V |
±(1.5% + 5) |
1V |
||
Frequency: 40Hz~400Hz; |
||||
Frequency of 400V and 600V: 40Hz~100Hz |
||||
DC Current
|
40.00mA |
± (1% + 2) |
10uA |
|
200.0mA |
± (1.5% + 2) |
100uA |
||
4.000A |
± (1.8% + 2) |
1mA |
||
10.00A |
± (3% + 2) |
10mA |
||
Overload protection: |
||||
Self restoring fuse: 200mA/250V, 4A and 10A range no fuse. |
||||
AC Current
|
40.00mA |
± (1.3% + 2) |
10uA |
|
400.0mA |
± (1.8% + 2) |
100uA |
||
4.000A |
± (2% + 3) |
1mA |
||
10.00A |
± (3% + 5) |
10mA |
||
Frequency: 40Hz~400Hz; |
||||
Self restoring fuse: 200mA/250V, 4A and 10A range no fuse. |
||||
Resistance
|
400.0Ω |
±(1% + 3) |
0.1Ω |
|
4.000KΩ |
±(1.2% + 5) |
1Ω |
||
60.00KΩ |
|
10Ω |
||
60.00KΩ |
|
10Ω |
||
400.0KΩ |
|
100Ω |
||
400.0KΩ |
|
1KΩ |
||
40.00MΩ |
± (1.5%±3) |
10KΩ |
||
Capacitance
|
40.00nF |
±(3% + 5) |
10pF |
|
400.0nF |
|
100pF |
||
4.000uF |
|
1nF |
||
40.00uF |
|
10nF |
||
100.0uF |
|
100nF |
||
Overload protection: 220Vrms |
||||
Diode |
0V~1.0V |
|||
On-Off |
<50Ω |
|||
General Specifications |
||||
Display |
||||
Display Type |
2.8 inch64K color TFT |
|||
Display Resolution |
320 horizontal by 240 vertical pixels |
|||
Display Contrast |
Adjustable |
|||
Power Supply |
||||
Supply Voltage |
100V-240VAC, 50Hz-60Hz; DC INPUT: 5VDC, 2A |
|||
Power Consumption |
<2.5W |
|||
Fuse |
T, 3A |
|||
Battery |
2600mA*2 |
|||
Environmental |
||||
Operating Temperature |
0~50 °C (32~122 °F) |
|||
Storage Temperature |
-40~+71 °C (-40~159.8 °F) |
|||
Humidity
|
≤+104℉(≤+40°C): ≤90% relative humidity |
|||
106℉~122℉ (+41°C ~50°C): ≤60% relative humidity |
||||
Cooling Method |
Convection |
|||
Altitude
|
Operating and |
3,000m (10,000 feet) |
||
Nonoperating |
|
|||
Mechanical Shock
|
Random Vibration |
0.31gRMS from 50Hz to 500Hz, 10 minutes on each axis |
||
Nonoperating |
2.46gRMS from 5Hz to 500Hz, 10 minutes on each axis |
|||
Operating |
50g, 11ms, half sine |
|||
Mechanical |
||||
Dimension |
199 x 98x 40mm (L x W x H) |
|||
Weight |
624g |
|||
Standard Accessories |
Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 |
Probe*1,Clip Probe*2, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 |
Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 |
Probe*1,Clip Probe*1, Type Charging Cable*1, Power Adapter*1, Multimeter Probe*1 |
Just leave your email or phone number on the contact form so we can provide you with more services!